Home Information
1.5 hp

Up 1.5 hp 2 hp 2 hp CF 2.5 hp 2.5 hp CG&H 3 hp 4 hp 5 hp

MODELS 0150-CA-*

MODELS 0150-CB-*

RATING CONDITIONS FOR AIR CONDITIONING: 65ºF RETURN GAS * 0ºF SUBCOOLING * 95ºF AMBIENT (AIR OVER) * OPERATION AT 60HZ

Capacity (BTU/Hour) At The Indicated Evaporating Temperature

Condensing

0

5

10

15

20

25

30

35

45

55

Temperature

-17.8

-15.0

-12.2

-9.4

-6.7

-3.9

-1.1

1.7

7.2

12.8

ºF

ºC

70

21.1

8710

10220

11910

13780

15820

18030

20410

22970

28600

34900

80

26.7

7860

9280

10860

12610

14530

16610

18850

21260

26560

32500

90

32.2

7040

8370

9850

11490

13280

15240

17340

19610

24590

30190

100

37.8

6230

7470

8850

10390

12070

13900

15880

18000

22690

27950

110

43.3

5410

6560

7860

9300

10870

12590

14440

16430

20830

25760

120

48.9

5640

6850

8190

9670

11270

13010

14870

18990

23610

130

54.4

5810

7060

8440

9940

11560

13300

17150

21470

140

60.0

5890

7170

8570

10090

11710

15300

19330

Power in Watts At The Indicated Evaporating Temperature

Condensing

0

5

10

15

20

25

30

35

45

55

Temperature

-17.8

-15.0

-12.2

-9.4

-6.7

-3.9

-1.1

1.7

7.2

12.8

ºF

ºC

70

21.1

940

960

990

1010

1030

1040

1050

1040

1000

910

80

26.7

960

1000

1040

1080

1110

1140

1160

1170

1160

1090

90

32.2

970

1030

1090

1140

1190

1230

1260

1290

1310

1280

100

37.8

980

1050

1130

1190

1260

1320

1370

1410

1460

1460

110

43.3

980

1060

1150

1240

1320

1390

1460

1520

1600

1640

120

48.9

1060

1160

1260

1360

1450

1530

1610

1730

1800

130

54.4

1150

1260

1380

1490

1590

1680

1840

1940

140

60.0

1240

1370

1500

1620

1730

1920

2060

Current in Amperes At The Indicated Evaporating Temperature

Condensing

0

5

10

15

20

25

30

35

45

55

Temperature

-17.8

-15.0

-12.2

-9.4

-6.7

-3.9

-1.1

1.7

7.2

12.8

ºF

ºC

70

21.1

4.2

4.3

4.4

4.4

4.5

4.5

4.5

4.5

4.4

4.2

80

26.7

4.3

4.4

4.5

4.5

4.6

4.6

4.7

4.7

4.7

4.5

90

32.2

4.3

4.4

4.5

4.6

4.7

4.8

4.9

4.9

4.9

4.9

100

37.8

4.4

4.5

4.6

4.7

4.9

5.0

5.0

5.1

5.2

5.2

110

43.3

4.4

4.5

4.7

4.8

5.0

5.1

5.2

5.3

5.5

5.5

120

48.9

4.5

4.7

4.9

5.0

5.2

5.4

5.5

5.7

5.9

130

54.4

4.6

4.9

5.1

5.3

5.5

5.6

6.0

6.2

140

60.0

4.8

5.1

5.3

5.5

5.8

6.2

6.5

Mass Flow in Pounds per Hour Power At The Indicated Evaporating Temperature

Condensing

0

5

10

15

20

25

30

35

45

55

Temperature

-17.8

-15.0

-12.2

-9.4

-6.7

-3.9

-1.1

1.7

7.2

12.8

ºF

ºC

70

21.1

102

118

138

160

186

215

247

281

356

440

80

26.7

96

112

131

154

179

207

237

270

340

420

90

32.2

88

105

125

147

172

199

228

259

325

390

100

37.8

80

97

117

140

164

191

219

248

311

380

110

43.3

69

88

109

131

156

182

209

237

296

360

120

48.9

76

98

121

146

171

198

226

282

338

130

54.4

84

108

133

159

186

212

266

318

140

60.0

93

118

144

171

197

248

297

All performance values are nominal and will be realized (+/- 5%) after a break-in period of a minimum of 24 hours.

Designs, and therefore performance, are subject to change without notice.

Figures in italics are restricted to a maximum return-gas temperature of 40ºF

Home ] Information ] Up ] [ 1.5 hp ] 2 hp ] 2 hp CF ] 2.5 hp ] 2.5 hp CG&H ] 3 hp ] 4 hp ] 5 hp ]

SCAN2.jpg (11933 bytes)Andover Protection Systems Inc.
63 Flushing Avenue, Bldg 5, Brooklyn, NY 11205 USA
Phone: 718-643-1110     FAX: 718-797-1120     E-mail: Click to E-mail
Click to E-mail with questions or comments about this web site.
Copyright© 1998-2006 Figment Design
Last modified: June 09, 2006