2.5 hp

Up 1.5 hp 2 hp 2 hp CF 2.5 hp 2.5 hp CG&H 3 hp 4 hp 5 hp

MODELS 0250-CI-*

RATING CONDITIONS FOR AIR CONDITIONING: 65ºF RETURN GAS * 0ºF SUBCOOLING * 95ºF AMBIENT (AIR OVER) * OPERATION AT 60HZ

Capacity (BTU/Hour) At The Indicated Evaporating Temperature

Condensing

0

5

10

15

20

25

30

35

45

55

Temperature

-17.8

-15.0

-12.2

-9.4

-6.7

-3.9

-1.1

1.7

7.2

12.8

ºF

ºC

70

21.1

11910

14190

16710

19490

22540

25860

29470

33370

42100

52120

80

26.7

11200

13390

15810

18480

21400

24590

28050

31790

40160

49780

90

32.2

10430

12510

14810

17350

20130

23160

26450

30020

38000

47170

100

37.8

9620

11570

13740

16130

18740

21600

24710

28080

35630

44320

110

43.3

8810

10610

12620

14840

17280

19940

22850

26000

33080

41260

120

48.9

9650

11490

13520

15750

18210

20890

23810

30380

38010

130

54.4

10360

12180

14200

16430

18870

21530

27560

34590

140

60.0

10870

12650

14630

16800

19190

24640

31050

Power in Watts At The Indicated Evaporating Temperature

Condensing

0

5

10

15

20

25

30

35

45

55

Temperature

-17.8

-15.0

-12.2

-9.4

-6.7

-3.9

-1.1

1.7

7.2

12.8

ºF

ºC

70

21.1

1350

1410

1470

1510

1550

1570

1600

1610

1620

1600

80

26.7

1500

1570

1640

1700

1750

1790

1830

1860

1890

1900

90

32.2

1610

1700

1790

1870

1930

1990

2040

2090

2150

2190

100

37.8

1690

1800

1910

2010

2090

2170

2240

2300

2400

2470

110

43.3

1740

1880

2000

2120

2230

2320

2410

2490

2630

2740

120

48.9

1920

2070

2210

2340

2450

2570

2670

2850

3000

130

54.4

2100

2270

2420

2560

2700

2820

3050

3250

140

60.0

2300

2480

2650

2810

2960

3230

3480

Current in Amperes At The Indicated Evaporating Temperature

Condensing

0

5

10

15

20

25

30

35

45

55

Temperature

-17.8

-15.0

-12.2

-9.4

-6.7

-3.9

-1.1

1.7

7.2

12.8

ºF

ºC

70

21.1

6.8

7.1

7.3

7.4

7.6

7.7

7.7

7.8

7.8

7.8

80

26.7

7.4

7.8

8.0

8.3

8.5

8.6

8.8

8.9

9.0

9.1

90

32.2

7.9

8.3

8.6

9.0

9.2

9.5

9.7

9.9

10.1

10.3

100

37.8

8.2

8.7

9.1

9.5

9.9

10.2

10.5

10.8

11.2

11.5

110

43.3

8.4

9.0

9.5

10.0

10.4

10.9

11.2

11.6

12.2

12.7

120

48.9

9.1

9.8

10.4

10.9

11.4

11.9

12.3

13.1

13.8

130

54.4

10.0

10.7

11.3

11.9

12.5

13.0

14.0

14.9

140

60.0

10.9

11.6

12.3

13.0

13.7

14.9

16.0

Mass Flow in Pounds per Hour Power At The Indicated Evaporating Temperature

Condensing

0

5

10

15

20

25

30

35

45

55

Temperature

-17.8

-15.0

-12.2

-9.4

-6.7

-3.9

-1.1

1.7

7.2

12.8

ºF

ºC

70

21.1

142

169

200

233

270

310

355

403

513

640

80

26.7

137

165

195

228

265

305

350

398

508

640

90

32.2

133

159

189

222

259

299

343

391

500

630

100

37.8

128

154

183

215

251

290

334

381

489

620

110

43.3

122

147

176

207

242

280

322

369

475

600

120

48.9

141

168

198

231

268

309

354

458

580

130

54.4

159

187

219

254

294

337

437

556

140

60.0

175

205

239

276

318

414

529

All performance values are nominal and will be realized (+/- 5%) after a break-in period of a minimum of 24 hours.

Designs, and therefore performance, are subject to change without notice.

Figures in italics are restricted to a maximum return-gas temperature of 40ºF

Home ] Information ] Up ] 1.5 hp ] 2 hp ] 2 hp CF ] [ 2.5 hp ] 2.5 hp CG&H ] 3 hp ] 4 hp ] 5 hp ]

SCAN2.jpg (11933 bytes)Andover Protection Systems Inc.
63 Flushing Avenue, Bldg 5, Brooklyn, NY 11205 USA
Phone: 718-643-1110     FAX: 718-797-1120     E-mail: Click to E-mail
Click to E-mail with questions or comments about this web site.
Copyright© 1998-2006 Figment Design
Last modified: June 09, 2006