Home Information
3 hp

Up 1.5 hp 2 hp 2 hp CF 2.5 hp 2.5 hp CG&H 3 hp 4 hp 5 hp

MODELS 0300-CJ-*

MODELS 0300-CK-*

RATING CONDITIONS FOR AIR CONDITIONING: 20ºF SUPERHEAT * 15ºF SUBCOOLING * 95ºF AMBIENT (AIR OVER) * OPERATION AT 60HZ

Capacity (BTU/Hour) At The Indicated Evaporating Temperature

Condensing

-10

0

10

20

30

40

45

50

55

Temperature

-23.3

-17.8

-12.2

-6.7

-1.1

4.4

7.2

10.0

12.8

ºF

ºC

80

26.7

12100

17200

23600

31600

41000

52200

58400

65100

72300

90

32.2

10600

15300

21300

28800

37800

48500

54500

60900

67800

100

37.8

13400

19000

26000

34500

44700

50400

56600

63200

110

43.3

16800

23300

31300

40900

46300

52200

58500

120

48.9

14700

20600

28000

37000

42100

47600

53500

130

54.4

18000

24700

33000

37700

42900

48400

140

60.0

21400

28900

33300

38000

43100

150

65.6

18100

24800

28700

33000

37600

Power in Watts At The Indicated Evaporating Temperature

Condensing

-10

0

10

20

30

40

45

50

55

Temperature

-23.3

-17.8

-12.2

-6.7

-1.1

4.4

7.2

10.0

12.8

ºF

ºC

80

26.7

1640

1880

2080

2240

2360

2460

2500

2530

2550

90

32.2

1650

1950

2200

2400

2570

2710

2770

2820

2860

100

37.8

1990

2290

2540

2760

2940

3020

3090

3160

110

43.3

2340

2650

2920

3150

3260

3360

3450

120

48.9

2360

2730

3060

3350

3480

3610

3730

130

54.4

2780

3170

3520

3690

3840

3990

140

60.0

3250

3670

3870

4060

4250

150

65.6

3310

3800

4040

4260

4480

Current in Amperes At The Indicated Evaporating Temperature

Condensing

-10

0

10

20

30

40

45

50

55

Temperature

-23.3

-17.8

-12.2

-6.7

-1.1

4.4

7.2

10.0

12.8

ºF

ºC

80

26.7

6.1

6.7

7.1

7.4

7.7

7.8

7.9

7.9

7.9

90

32.2

6.1

6.8

7.4

7.8

8.1

8.4

8.5

8.6

8.6

100

37.8

6.9

7.5

8.1

8.6

9.0

9.1

9.3

9.4

110

43.3

7.6

8.4

9.0

9.5

9.7

9.9

10.1

120

48.9

7.7

8.5

9.3

10.0

10.3

10.5

10.8

130

54.4

8.6

9.6

10.4

10.8

11.1

11.5

140

60.0

9.8

10.8

11.3

11.7

12.2

150

65.6

10.0

11.1

11.7

12.3

12.8

Mass Flow in Pounds per Hour Power At The Indicated Evaporating Temperature

Condensing

-10

0

10

20

30

40

45

50

55

Temperature

-23.3

-17.8

-12.2

-6.7

-1.1

4.4

7.2

10.0

12.8

ºF

ºC

80

26.7

152

218

298

395

509

642

716

795

879

90

32.2

136

199

277

371

482

612

684

762

844

100

37.8

182

257

347

455

581

652

728

808

110

43.3

237

324

428

551

619

693

772

120

48.9

218

301

401

520

586

657

734

130

54.4

279

374

488

552

621

695

140

60.0

347

456

517

584

655

150

65.6

321

424

482

545

613

Energy Efficiency Rating (EER) in BTU/Watt-Hr At The Indicated Evaporating Temperature

Condensing

-10

0

10

20

30

40

45

50

55

Temperature

-23.3

-17.8

-12.2

-6.7

-1.1

4.4

7.2

10.0

12.8

ºF

ºC

80

26.7

7.4

9.2

11.4

14.1

17.4

21.2

23.4

25.8

28.4

90

32.2

6.4

7.8

9.7

12.0

14.7

17.9

19.7

21.6

23.7

100

37.8

6.8

8.3

10.2

12.5

15.2

16.7

18.3

20.0

110

43.3

7.2

8.8

10.7

13.0

14.2

15.5

16.9

120

48.9

6.2

7.5

9.2

11.0

12.1

13.2

14.4

130

54.4

6.5

7.8

9.4

10.2

11.2

12.1

140

60.0

6.6

7.9

8.6

9.4

10.2

150

65.6

5.5

6.5

7.1

7.7

8.4

All performance values are nominal and will be realized (+/- 5%) after a break-in period of a minimum of 24 hours.

Designs, and therefore performance, are subject to change without notice.

Home ] Information ] Up ] 1.5 hp ] 2 hp ] 2 hp CF ] 2.5 hp ] 2.5 hp CG&H ] [ 3 hp ] 4 hp ] 5 hp ]

SCAN2.jpg (11933 bytes)Andover Protection Systems Inc.
63 Flushing Avenue, Bldg 5, Brooklyn, NY 11205 USA
Phone: 718-643-1110     FAX: 718-797-1120     E-mail: Click to E-mail
Click to E-mail with questions or comments about this web site.
Copyright© 1998-2006 Figment Design
Last modified: June 09, 2006